4 error messages, Error messages – Lenze E94ARNE Regenerative power supply User Manual
Page 126

9400 regenerative power supply module | Parameter setting
"CAN on board" system bus
Parameter data transfer
126
L
EDS94ARNExxxx EN 2.3 - 06/2014
6.7.2.4
Error messages
When an error has occurred, the addressed node generates a telegram with the "Error
response" command (0x80).
The telegram contains the index and subindex of the code in which the error occurred.
Bytes 5 ... 8 contain the error code.
– The error codes are standardised according to DS301 V4.02.
– The error code is displayed inverse to the read direction (see below example).
Example
Error code "0x06 04 00 41" in bytes 5 ... 8:
1st byte
2nd byte
3rd byte
4th byte
5th byte
6th byte
7th byte
8th byte
Command
Index
Subindex
Error code
0x80
(128)
Low byte
High byte
Low word
High word
Low byte
High byte
Low byte
High byte
1st byte
2nd byte
3rd byte
4th byte
5th byte
6th byte
7th byte
8th byte
Command
Index
Subindex
Error code
0x41
0x00
0x04
0x06