Maintenance and troubleshooting, Cooling flow – MK Diamond MK-770 User Manual

Page 32

Advertising
background image

MK-770

Revision 06/05, Effective Date June 17, 2005

Page 32

MAINTENANCE AND TROUBLESHOOTING

3. Cooling Flow:







































































(A)

Check cooling flow Adjusting

Clamp open

(C)

Place Pump into a bucket of

water and check flow

(B)

Remove the Cooling Transfer

Tube from the Blade Guard

inlet

(D)

Remove the Cooling Transfer

Tube and check flow

(E)

Remove the Pump Discharge

Fitting and check

(I)

Remove the Blade Guard

Intake Fitting

(H)

Remove the Pump Casing and

check for restriction; check

Impeller damage

(G)

Remove the 3 Pump Casing

Retaining Screws

(F)

Remove the Pump Intake

Screen and check for debris

Go to

Step C

Check Impeller

for damage

If flow exists,

go to Step E

If flow exists,

go to Step D

Pull Tab

to loosen

If flow exists,

go to Step A

Pull to

remove

Cover Pump

suction with water

Pull to

remove

If flow exists,

go to Step F

Remove

Discharge Fitting

Pull Intake Screen

to remove

If Screen clean,

go to Step G

Phillips

Screwdriver

Once Screws

removed, go

to Step H

Check for
restriction

If no damage

or restrictions,

go to Step I

Turn counter-

clockwise to

loosen

Go to

Step J

Intake Fitting

Advertising