Safety – MK Diamond MK-770 User Manual

Page 8

Advertising
background image

MK-770

Revision 06/05, Effective Date June 17, 2005

Page 8

SAFETY

To avoid the possibility of the appliance plug or receptacle getting wet, position the saw to one side
of a wall mounted receptacle. This will prevent water from dripping onto the receptacle or plug. A
"drip loop," shown in FIGURE 2, should be arranged by the user to properly position the power cord
relative to the power source.


The "drip loop" is that part of the cord below the level of the receptacle, or
the connector, if an extension cord is used. This method of positioning the
cord prevents the travel of water along the power cord and coming in
contact with the receptacle.
If the plug or receptacle gets wet, DO NOT unplug the cord. Disconnect
the fuse or circuit breaker that supplies power to the tool. Then unplug and
examine for presence of water in the receptacle.




Use only extensions cords that are intended for outdoor use. These extension cords are identified
by a marking "Acceptable for use with outdoor appliances; store indoors while not in use." Use only
extension cords having an electrical rating not less than the rating of the product. Do not use
damaged extension cords. Examine extension cords before using and replace if damaged. Do not
abuse extension cords and do not yank on any cord to disconnect. Keep cords away from heat and
sharp edges. Always disconnect the extension cord from the receptacle before disconnection the
product form the extension cord.

To reduce the risk of electrocution, keep all connections dry and off the ground. Do not touch the
plug with wet hands.


Use of undersize extension cords result in low voltage to the motor that can result in motor burnout
and premature failure. MK Diamond warns that equipment returned to us showing signs of being run
in a low voltage condition, through the use of undersized extension cords will be repaired or replaced
totally at the customers expense. There will be no warranty claim.

To choose the proper extension cord,

Locate the length of extension cord needed in TABLE 1 below.

• Once the proper length is found, move down the column to obtain the correct AWG size required

for that length of extension cord.

Extension Cord Minimum Gage for Length

Volts

Total Length of Cord in Feet

120V

25 ft.

50 ft.

100 ft

150 ft.

AWG

AWG

AWG

AWG

14

12

Not Recommended

TABLE 1




Supporting
Surface

Power
Tool

Drip Loop

Power
Cord

FIGURE 2

Advertising