Maintenance and troubleshooting, Troubleshooting – MK Diamond MK-145 220 Volt User Manual

Page 25

Advertising
background image

MK Diamond Products Inc. Customer Service Department (800) 421-5830

MK-145

Revision 09/04, Effective date – September 23, 2004

Page

25

MAINTENANCE and TROUBLESHOOTING:

TROUBLESHOOTING:

Turn the ON/OFF switch to the OFF position and unplug the saw from the
power source before performing any troubleshooting procedure.


Motor Stops Turning:

STEP ACTION

1.

Verify Plugs Fully Connected
• If not fully connected, reconnect plugs and turn

on the saw

• If fully connected, go to step 2





2.

Check Ground Fault Circuit Interrupter (GFCI)
• If the GFCI is tripped reset it and turn on the

saw

• If the GFCI is not tripped, go to step 3





3.

Verify Circuit Breaker at least 15 Amps
• If the circuit breaker is not 15 amps, move the

saw to a 15-amp circuit breaker and turn on
saw

• If the circuit breaker is 15 amps, go to step 4







4.

Verify Circuit Breaker Not Tripped
• If tripped, reset the breaker once and turn on

the saw

• If the saw trips again, proceed to step 6

• If the circuit breaker is not tripped, go to step 5







5.

Check Power Source Voltage is 230 volts
• If power source is not at 230v move the saw to

another circuit and turn on the saw

• If the power source is at 230v, go to step 6






7.

Return the MK-145 for Repair
• Return the MK-145 for repair per the Return

Instructions section of this procedure










Verify all

Connections

Check GFCI

Check for Correct

Breaker Size

(15 amp)

Check for

Tripped Breaker

Check for

Proper Voltage

Return to

MK Diamond

for Repair

Advertising