Caution – MK Diamond BX-4 User Manual

Page 35

Advertising
background image

BX-4

35

Disconnect unit from power supply.

CAUTION

REPLACEMENT OF PUMP:


Step A:
Using 4 mm hex key, remove 4 Pump cover
Retaining Screws.

Step B: Remove pump cover (1).

Step C: Disconnect electric terminals from pump.

Remove tubes from both ends of pump. (Visually inspect
tube condition. Replace tubes, if necessary).

Step D: Re-connect electric terminals & tubes to pump.

Step E: Secure tubes with tube clamps.

Step F: Position & hold pump in the Cutting Head with

Pump Cover (1). Secure all screws.

Bent or kinked tubes may prevent free flow of water and
may shorten pump life.

CAUTION

MISTING SYSTEM OPERATION, MAINTENANCE & TROUBLESHOOTING

Cutting
Head

1