NO MIST:

Step A: Check Pump Switch & Saw are on.

Step B: Remove Nozzle & inspect. Nozzle should be open & free of all debris

Step C: Inspect water intake filter. Ensure filter is free of excess debris & water

in container is clean.

Step D: Ensure tubing is undamaged & free of kinks or sharp bends.

Step E: Check tubing connectors to ensure tubing is fully inserted in connector.

Step F: Check Pump to ensure it is operating properly. If not, contact MK Diamond.