MTS TestLine User Manual

Page 94

Advertising
background image

Set up a Scope to compare the command signal to the resulting feedback. Enlarge the scope if
necessary, and then set up the scope as follows:

Y1 parameters:

•

Channel — Ch1 (or other depending on your configuration)

•

Signal — Command

•

Unit — kN

•

Units/div — 0.1000

•

Offset — 0.3000

Y2 parameters:

•

Channel — Ch1 (or other depending on your configuration)

•

Signal — Force

•

Unit — kN

•

Units/div — 0.1000

•

Offset — 0.3000

Time:

•

Trace Time — 5.0000 s

5. Set the HPU and HSM to Power High.

94 | MTS TestLine Test System Operation

Running the Example HCF Test

Advertising