New Era NE-1600 Multi-Phaser Programmable Syringe User Manual

Page 4

Advertising
background image

New Era Pump Systems Inc.

WWW.SYRINGEPUMP.COM

Model NE-1600/NE-1800 Multi-Phaser™

Publication #1200-02

iii

8/1/14

6.1.1

Default Volume Units .................................................................................................................................... 12

6.1.2

Changing Volume Units ................................................................................................................................. 12

6.2

Start/Stop Triggers .............................................................................................................................. 13

6.3

Operating the Pump ............................................................................................................................ 13

6.4

Purging .................................................................................................................................................. 13

6.5

Changing the Pumping Rate and Direction While Pumping ........................................................... 13

6.6

Volume Dispensed ................................................................................................................................ 13

6.7

Resuming When Paused ...................................................................................................................... 14

6.8

Pump Stalled ........................................................................................................................................ 14

7.

Setup Configuration...................................................................................................................... 14

7.1

Power Failure Mode ............................................................................................................................ 15

7.2

Low Noise Mode ................................................................................................................................... 15

7.3

Audible Alarm Enable ......................................................................................................................... 15

7.4

TTL I/O Operational Trigger Default Configuration ...................................................................... 15

7.5

TTL I/O Directional Control Input Configuration ........................................................................... 16

7.6

Pump Motor Operating TTL Output Configuration ....................................................................... 16

7.7

Keypad Lockout ................................................................................................................................... 16

7.8

Keypad Beep Enable ............................................................................................................................ 16

7.9

RS-232 Pump Network Configuration ............................................................................................... 17

8.

Pumping Program ......................................................................................................................... 17

8.1

How to Enter Pumping Programs ...................................................................................................... 18

8.1.1

Pumping Program Phase Number .................................................................................................................. 18

8.2

Pumping Program Edit Functions ..................................................................................................... 19

8.3

Program Function Descriptions .......................................................................................................... 19

8.3.1

‘rAtE’: Rate Function ..................................................................................................................................... 19

8.3.2

‘FILL’: Fill Function ...................................................................................................................................... 19

8.3.3

‘Incr’: Increment Rate Function .................................................................................................................... 20

8.3.4

‘DEcr’: Decrement Rate Function................................................................................................................. 20

8.3.5

‘StoP’: Stop Pumping Operation and End the Program ................................................................................ 20

8.3.6

‘JP:nn’: Jump to Phase .................................................................................................................................. 20

8.3.7

'Pr:In': Sub-Program Selection Input ............................................................................................................. 20

8.3.8

'Pr:nn': Sub-Program Start Label .................................................................................................................... 21

8.3.9

‘LP:ST’: Define Starting Phase of Loop ....................................................................................................... 21

8.3.10

‘LP:EN’: Define Continuous Loop End ........................................................................................................ 21

8.3.11

‘LP:nn’: Define Loop End and Loop Repetitions ......................................................................................... 21

8.3.12

'PS:nn': Pause Pumping ................................................................................................................................. 21

8.3.13

'IF:nn': Jump to Phase If External Trigger .................................................................................................... 22

8.3.14

'Et:nn': Setup Event Trigger Jump Phase ...................................................................................................... 22

8.3.15

'ES:nn': Setup Event Square Wave Trigger Jump Phase ................................................................................ 22

8.3.16

‘Et:rS’: Event Reset ....................................................................................................................................... 22

8.3.17

‘CLr.d’: Clear Total Volume Dispensed ........................................................................................................ 22

8.3.18

‘tr:aa’: Override Operational Trigger Configuration ...................................................................................... 23

8.3.19

‘Out.n’: Set TTL Output Pin ......................................................................................................................... 23

8.3.20

‘bEEP’: Beep................................................................................................................................................. 23

8.4

Pumping Program Examples .............................................................................................................. 23

Advertising