10.3 TTL I/O Control from RS-232

The logic levels of pins 2, 3, 4, and 6 can be queried from an attached computer using the RS-232 ‘IN’
command.

The output logic level of pin 5 can be set with the RS-232 ‘OUT’ command.

11. Appendix

11.1 RS-232 Command Summary

<command> =>
DIA [ < float > ]

Syringe inside diameter

PHN [ < phase data > ]

Program Phase number

FUN [ < phase function > ]

Program Phase function

< phase function > =>

RAT

Pumping rate. ‘RATE’

FIL

Fill syringe to volume dispensed. ‘FILL’

INC

Increment rate. ‘INCR’

DEC

Decrement rate. ‘DECR’

STP

Stop pump. ‘STOP’

JMP <phase data>

Jump to Program Phase. ‘JP:nn’

PRI

Sub-Program Selection Input. 'Pr:In'

PRL <number data>

Sub-Program Start Label definition. 'Pr:nn'

LPS

Loop starting Phase. ‘LP:ST’

LOP <count data>

Loop to previous loop start ‘nn’ times. ‘LP:nn’

LPE

Loop end Phase. ‘LP:EN’

PAS <number data>

Pauses pumping for ‘nn’ seconds. ‘PS:nn’

PAS [n.n]

Pauses pumping for 'n.n' seconds. 'PS:n.n'

IF <phase data>

If Program input low, jump to Program Phase. ‘IF:nn’

EVN <phase data>

Set event trigger. ‘EV:nn’

EVS <phase data>

Set event square wave trigger. 'ES:nn'

EVR

Event trigger reset. ‘EV:RS’

CLD

Clear total dispense volume. ‘CLR.D’

TRG <nn>

Override operational trigger configuration ‘tr:aa’

BEP

Sound short beep. ‘BEEP’

OUT { 0 | 1 }

Set programmable output pin. ‘OUT.n’

RAT [C | I ] [ <float> [ UM | MM | UH | MH ] ] Pumping rate
VOL [ <float> | <volume units>]

Volume to be Dispensed, or set Volume units

DIR [ INF | WDR | REV | STK ]

Pumping direction

RUN [ <phase data> ]

Starts the Pumping Program

[E [<phase data>] ]

Pumping Program event trigger

PUR

Start purge

STP

Stop/pauses the Pumping Program or purge

DIS

Query volume dispensed

CLD { INF | WDR }

Clear volume dispensed

SAF [ <n> [ <n> [ <n> ] ] ]

Safe communications mode

LN [ 0 | 1]

Low motor noise mode

AL [ 0 | 1]

Alarm buzzer mode

PF [ 0 | 1]

Power failure auto-restart mode

TRG [ FT | FH | F2 | LE | ST | T2 | SP | P2 | RL | RH | SL | SH |OF ]

Operational trigger default mode

DIN [ 0 | 1]

Directional input control mode

ROM [0 | 1]

Pump Motor Operating TTL output mode

LOC [ P ] [ 0 | 1]]

Keypad lockout mode or Program Entry Mode lockout

BP [ 0 | 1]

Key and Notification beep mode

OUT 5 { 0 | 1 }

Set TTL output level

IN { 2 | 3 | 4 | 6 }

Query TTL input level

BUZ [ 0 | { 1 [ < n > ] } ]

Buzzer control

VER

Query firmware version

System Commands: Valid regardless of current network address

*ADR [ <n> [<n>] [ B <baud-rate>] ]

Network address and baud rate

*ADR [ DUAL | RECP | ALTR ]

Set Reciprocating, Dual, or Alternating pumping mode