Warning

1.

About the use of the liquid and cooling water

„ Please do not use the liquid with the explosion

and toxicity.

„ Please do not mix water when you use oil in

the examination tank. (BH400/500)

„ Please do not flush cold water when using at

high temperatures. (BH400/500)

Caution

1.

Please do the method of installing the hose correctly.

„ Please detach flexibility pipe or nipple for the

short-circuit and install the attached hose
entrance when using as a circulation tank.
Securely connect to prevent water leak. When
using silicon oil as bath liquid, select a hose
resistive to silicon oil (e.g. fluorine rubber).

2.

Notes concerning liquid used

Density of ethanol

Density of ethanol

Density of ethanol

Density of ethanol

Wt %

Wt %

Wt %

Wt %

Vo1 %

Vo1 %

Vo1 %

Vo1 %

Coagulation

Coagulation

Coagulation

Coagulation

point (

point (

point (

point (℃

℃))))

4.8

6.0

-2.0

11.3

14.0

-5.0

13.8

17.0

-6.1

16.4

20.2

-7.5

17.5

21.5

-8.7

18.8

23.1

-9.4

20.3

24.8

-10.6

22.1

27.0

-12.2

24.2

29.5

-14.0

26.7

32.4

-16.0

29.9

36.1

-18.9

33.8

40.5

-23.6

39.0

46.3

-28.7

46.3

53.8

-33.9

„ The liquid poured into the examination tank

must use water or alcoholic solution.
(BH200/300)

„ The liquid poured into the examination tank

must use water or the silicon oil. (BH400/500)

„ It evaporates for water and alcohol, etc. while

using .Please replenish sometimes.

„ Please use the ethyl alcohol solution about

alcohol .Be careful please not to freeze
referring to a right table in proportion to the
service temperature. Do not use neither
automotive antifreeze nor the ethylene glycol
liquid. (BH200/300)

„ Using well water or bad-quality water will cause

accumulation of scale and copestone on the
heater pump, etc. Be sure to use distilled water
or pure water to prevent performance
deterioration or malfunction.

„ The viscosity must use the one to 50CST at

80

℃ or more about the silicon oil.

3.

Attention in handling

„ Please do not sprinkle water on the control part

and the operation panel. When water splashes
to an internal electrical component, the leak
and the electric shock are caused.

„ The upper surface in the tank etc. become

high temperatures, too, when using at the high
temperature. Please note handling enough.

Nipple

Flexibility pipe for the short-circuit

hose entrance

hose