Bulletin 284e troubleshooting, Fault definitions – Rockwell Automation 281E ArmorStart EtherNet/IP - Getting Started User Manual
Page 30

30 ArmorStart EtherNet/IP Distributed Motor Controller Getting Started
Publication 280E-QS001B-EN-P – February 2011
Bulletin 284E
Troubleshooting
Fault Definitions
Some of the Bulletin 284E ArmorStart Distributed Motor Controller faults are
detected by the internal hardware of the ArmorStart, while others are detected by
the internal drive. For internal drive faults, the internal hardware of the
ArmorStart simply polls the drive for the existence of faults and reports the fault
state. No fault latching is done by the internal hardware of the ArmorStart for
these faults. The PrFlt ResetMode parameter (Parameter 23) determines the
Auto Resettability of only the faults that are detected on the main control board.
The Auto Resettability of the faults that are detected in the internal drive is
controlled by internal drive parameters, refer to Table 9. The following flowchart
for Bulletin 284E units, is provided to aid in quick troubleshooting.
Figure 38 - Bulletin 284E Control Module LED Status
Faulted Display
See
Table 9
Fault
LED
Network
LED
Yes
No
See
Table 6
See
Table 12
Actions
Motor will
not start
Define Nature
of the
Problem