Default input and output (i/o) assembly formats – Rockwell Automation 281E ArmorStart EtherNet/IP - Getting Started User Manual
Page 39

Publication 280E-QS001B-EN-P – February 2011
ArmorStart EtherNet/IP Distributed Motor Controller Getting Started 39
Default Input and Output (I/O) Assembly Formats
The tables below identify the default information produced and consumed by
Bulletin 280E, 281E and 284E. For additional formats and advance
configurations please reference the user manual.
Defaults for Standard Distributed Motor Controllers
Figure 42 – Example of RSLogix
5000 Status Assembly Table
Table 18 - Instance 150
Produce Assembly - Instance 150 "Starter Status" - 280E/281E Starters
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
1
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
2
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
3
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
4
Ready
Running
Rev
Running
Fwd
Warning Tripped
5
140M On
HOA
Input 4
Input 3
Input 2
Input 1
6
Net Out 7
Net Out 6
Net Out 5 Net Out 4
Net Out 3
Net Out 2
Net Out 1 Net Out 0
7 Logic
Enable
Net Out
14
Net Out
13
Net Out
12
Net Out 11
Net Out 10
Net Out 9 Net Out 8
8
Value of the parameter pointed to by "Parameter 13 Prod Assy Word 0" (low byte)
9
Value of the parameter pointed to by "Parameter 13 Prod Assy Word 0" (high byte)
10
Value of the parameter pointed to by "Parameter 14 Prod Assy Word 1" (low byte)
11
Value of the parameter pointed to by "Parameter 14 Prod Assy Word 1" (high byte)
12
Value of the parameter pointed to by "Parameter 15 Prod Assy Word 2" (low byte)
13
Value of the parameter pointed to by "Parameter 15 Prod Assy Word 2" (high byte)
14
Value of the parameter pointed to by "Parameter 16 Prod Assy Word 3" (low byte)
15
Value of the parameter pointed to by "Parameter 16 Prod Assy Word 3" (high byte)