Chapter 4

Configurable functions

Application

With the help of the SCD software you can configure the SafeZone Mini for the required application. Depending on
whether you select a stationary or a mobile application, different configuration options are available:

Table 4: Comparison of mobile and

stationary applications

Resolution

The maximum protective field range

 depends on the configured resolution. The following table shows the related

maximum protective field range at the resolutions that can be set:

Table 5: Maximum protective field

range at different resolutions

Note

The warning field can be configured to up to 8 m (26.25 ft) for all resolutions. The detection capability within the warning
field is dependent on the remission of the objects to be detected (see Chapter 12, “Technical Specifications” on page 55).

Basic response time

The basic response time of the SafeZone Mini is 80 ms.

Note

You may need to add supplements to the basic response time due to multiple sampling (see Chapter 12, “OSSD response
times” on page 55).

Maximum protective field range

Depending on the configured resolution used (see Chapter 4, “Resolution” on page 16), the maximum protective field
range of the safety laser scanner is shown in the SCD software.

Note

The maximum protective field range of the SafeZone Mini must be sufficient to cover the calculated protective field size
including the necessary supplements (see Chapter 5, “Protective field size” on page 25).

In mobile applications a resolution of only 70 mm (2.8 in.) is required for leg detection.

Radial distance to the safety scanner.

Mobile applications [mm (in.)]

Stationary applications [mm (in.)]

Resolution

30 (1.2) (hand detection with smaller protective field
size)

40 (1.6) (hand detection with larger protective field
size)

50 (2.0) (leg detection with smaller protective field
size)

70 (2.8) (leg detection with larger protective field
size)

30 (1.2) (hand detection with smaller protective field
size)

40 (1.6) (hand detection with larger protective field
size)

50 (2.0) (leg detection with smaller protective field
size)

70 (2.8) (leg detection with larger protective field size)

150 (5.9) (whole body detection)

Manipulation prevention
The safety laser scanner checks whether in any 90° segment all measured values correspond to the maximum distance
value that can be measured.
If this is the case, the SafeZone Mini shuts down after

2 hours and signals

.

If this the case, the SafeZone Mini shuts down after

5 seconds and signals

.

Configured resolution [mm (in.)]

Maximum protective field range [m (ft)]

2 m

3 m

30 (1.2) – (hand detection)

1.25 (4.1)

1.25 (4.1)

40 (1.6) – (hand detection)

1.60 (5.2)

1.60 (5.2)

50 (2.0) – (leg detection)

2.00 (6.6)

2.10 (6.89)

70 (2.8) – (leg detection)

2.00 (6.6)

3.00 (9.84)

150 (5.9) (whole body detection)

3.00 (9.84)