Checklist for the manufacturer – Rockwell Automation 442L-SFZNMN SafeZone Mini Safety Laser Scanner User Manual User Manual

Page 72

Advertising
background image

70

Rockwell Automation Publication 10000337275 Ver 01—October 2014

Chapter 14

Annex

Checklist for the manufacturer

Have the safety rules and regulations been observed in compliance with the directives/standards
applicable to the machine?

Are the applied directives and standards listed in the declaration of conformity?

Does the protective device fulfill the required PL/SILCL and PFHd according to EN ISO 13 849-1/EN 62 061
and the type according to EN 61496-1?

Is the access to the hazardous area/hazardous point only possible through the protective field of the ESPE?

Have measures been taken to prevent and monitor unauthorized presence in the hazardous area when
hazardous area/hazardous point protection (mechanical protection) and have these been secured
against removal?

Are additional mechanical protective measures fitted and secured against manipulation, which prevent
reaching under, over, and around the ESPE?

Has the maximum stopping and/or stopping/run-down time of the machine been measured, specified
and documented (at the machine and/or in the machine documentation)?

Has the ESPE been mounted such that the required minimum distance from the nearest hazardous
point has been achieved?

Are the ESPE devices properly mounted and secured against manipulation after adjustment?

Are the required protective measures against electric shock in effect (protection class)?

Is the control switch for resetting the protective device (ESPE) or restarting the machine present and
correctly installed?

Are the outputs of the ESPE (OSSDs, ASInterface Safety at Work) integrated in compliance with the
required PL/SILCL according to EN ISO 13 8491/EN 62 061 and does the integration comply with the
circuit diagrams?

·

·

·

·

·

Has the protective function been checked in compliance with the test notes of this documentation?

Are the given protective functions effective at every setting of the operating mode selector switch?

Are the switching elements activated by the ESPE, e.g. contactors, valves, monitored?

Is the ESPE effective over the entire period of the dangerous state?

Once initiated, will a dangerous state be stopped when switching the ESPE on or off and when
changing the operating mode, or when switching to another protective device?

Has the information label for the daily check been attached so that it is easily visible for the operator?

Checklist for the manufacturer/installer for installing electro-sensitive protective
equipment (ESPE)

Details about the points listed below must be present at least during initial commissioning — they are, however, dependent on the
respective application, the specifcations of which are to be controlled by the manufacturer/installer.

IMPORTANT

This checklist should be retained and kept with the machine documentation to serve as reference
during recurring tests.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

No

Yes

No

Yes

No

Yes

No

Yes

No

Yes

No

Yes

No

Yes

No

Yes

No

Yes

No

Yes

No

Yes

No

Yes

No

Yes

No

Yes

No

Yes

No

Yes

No

Yes

No

Yes

This checklist does not replace the initial commissioning, nor the regular inspection by qualified safety personnel.

Advertising