Chapter, Application examples and connection diagrams – Rockwell Automation 442L-SFZNMN SafeZone Mini Safety Laser Scanner User Manual User Manual
Page 44

42
Rockwell Automation Publication 10000337275 Ver 01—October 2014
Chapter 7
Application examples and connection diagrams
Chapter
7
Application examples and connection diagrams
The examples shown are only provided as an aid for your planning. You may need to consider additional protection
measures for your application.
Stationary applications
Applications with one monitored area (SafeZone Mini)
Fig. 40: Hazardous area protection with
SafeZone Mini
The area is permanently monitored by the SafeZone Mini.
Fig. 41: Access protection with
SafeZone Mini
The access is monitored permanently. For safety against manipulation on the SafeZone Mini, e.g. the floor is used as a
reference. If the alignment of the SafeZone Mini changes (e.g. due to changes to the bracket), the SafeZone Mini switches
its OSSDs to the OFF state.
SafeZone Mini with one protective
field and one warning field —
mounted horizontally
SafeZone Mini with one protective
field —mounted vertically
Floor as reference