40

Rockwell Automation Publication 10000337275 Ver 01—October 2014

Chapter 6

Electrical installation

Notes

 Route all cables and connection cables such that they are protected from damage.
 Ensure that also the controller connected and all devices related to safety have the required category as per

EN ISO 13849­1 or the required performance level as per EN ISO 13849­1!

 If you use screened cables, lay the screen evenly around the connection terminal.
 Ensure that the SafeZone Mini is adequately protected electrically. You will find the electrical data necessary for

determining the correct fuse in Chapter 12, “Data sheet” on page 58.

System connection

You will find all the inputs and outputs on the SafeZone Mini on the round plug connector on the connecting cable.
Connect the SafeZone Mini using pre-assembled extension cables (see Table 10 on page 41).

Notes

All inputs and outputs on the SafeZone Mini are to be used only in the context specified.

The round plug connectors are coded. If you use plug connectors other than the connectors intended, any claims
against Rockwell Automation under the warranty will be rendered void.

Wiring in accordance with EMC regulations

The quality of the shield is essentially dependent on the quality of the connection of the screen. In principle the best
screening action can only be achieved with the connection of the shield at both ends using large area connections.
 If it is not possible to connect the screen via threaded fittings, connect the screen physically close, e.g. to a control

cabinet chassis using a metal clamp.

Notes

If there is a PE in an installation, it can be used for the connection of the FE. However a functional earth connection
(FE) is never allowed to be used as a PE!

Functional earth

To achieve the specified EMC safety, the functional earth FE must be connected (e.g. to the vehicle’s or system’s central
earth star point).

Round plug connector SafeZone Mini

Fig. 38: Round plug connector

SafeZone Mini

Pin assignment:

Table 9: Pin assignment of the

SafeZone Mini

Use the cordsets listed in

Table 18: Ordering information on page 65

to connect the SafeZone Mini.

8

4

1

2

3

6

7

5

Pin

Signal

Function

1

WF

Output for warning field 1

2

+24V DC

Supply voltage SafeZone Mini

3

I/O1

Universal I/O

4

I/O2

Universal I/O

5

OSSD1

Output signal switching device

6

OSSD2

Output signal switching device

7

0V DC

Supply voltage

8

FE/shield

Functional earth/shield

Housing

FE/shield

Functional earth/shield