Chapter, Technical specifications, Ossd response times – Rockwell Automation 442L-SFZNMN SafeZone Mini Safety Laser Scanner User Manual User Manual
Page 57

Rockwell Automation Publication 10000337275 Ver 01—October 2014
55
Chapter 12
Technical specifications
Chapter
12
Technical specifications
Fig. 48: Diagram scanning range
2 meter SafeZone Mini
Fig. 49: Diagram scanning range
3 meter SafeZone Mini
OSSD response times
The total response time of your application is dependent on …
•
The basic response time of the SafeZone Mini.
•
The multiple sampling set.
•
The OSSDs used.
•
The control inputs used.
500
5
0.1
0.2
0.5
1
2
50
20
10
1
2
5
10
20
50
100
200
Reflectors > 2000%
Reflective films > 300%
White plaster
Writing paper
Grey cardboard
Matte black paint
Black shoe leather
Re
mi
ss
ion (
%
)
Protective field
Warning field
Scanning range [m]
500
5
0.1 0.2
0.5
1
2
50
20
10
1
2
5
10
20
50
100
200
Reflectors > 2000%
Reflective films > 300%
White plaster
Writing paper
Grey cardboard
Matte black paint
Black shoe leather
Re
mi
ss
ion (%)
Protective field
Warning field
Scanning range [m]