46

Rockwell Automation Publication 10000337275 Ver 01—October 2014

Chapter 8

Configuration

Chapter

8

Configuration

Default delivery status

The SafeZone Mini is delivered in a non-configured default state.

The operational status is Waiting for configuration.

The seven­segment display indicates

.

On the SafeZone Mini the output signal switching devices (OSSDs) are in the OFF state, the red LED is

illuminated: .

Preparation of the
configuration

How to prepare the configuration:
 Make sure that the safety laser scanner has been correctly mounted and that the electrical connections are correct and

in place.

 Have the necessary tools at hand.

To configure the safety laser scanner you need:

SCD Software on CD­ROM or downloaded from www.ab.com/safety

PC/notebook with Windows NT 4/2000 Professional/XP/Vista/7 (32 Bit) and a serial RS-232 interface (PC/notebook
not included)

Service cable for connecting PC and SafeZone Mini

How to configure the SafeZone Mini with the aid of the SCD software:

To configure and perform diagnostics on the SafeZone Mini, directly connect the PC to the configuration connection to the
SafeZone Mini.

Fig. 46: Configuration connection

Two service cables of different lengths are available for the connection of the PC/notebook (see Chapter 13, “Accessories”
on page 65).

Notes

Ensure that the service cable is not laid in close proximity to high power electrical drives or cables carrying high power.
In this way you will avoid EMC effects on the service cable.

The service cable is only allowed to be connected for configuration and diagnostics. The service cable must be
disconnected and the protective cap fitted in operation.

Note

Use the password function in the SCD software and protect the configuration settings from unauthorized access. Also
ensure that the passwords are stored protected from unauthorized access.

.

Configuration connection

Advertising