Decommission and recycle the battery – Rockwell Automation 1758-RTU202 DataSite Hardware User Manual User Manual

Page 55

Advertising
background image

Publication 1758-UM001D-EN-P - June 2011

Operating the Controller

55

If the battery voltage should drop below 2.0 V, contact your Rockwell
Automation Support or your local Rockwell Automation representative to
arrange for a repair or exchange of the DataSite controller.

Decommission and Recycle the Battery

ATTENTION

The lithium battery is not user replaceable. Follow the
instructions in this section to remove the battery from the
DataSite unit for recycling when decommissioning the DataSite
unit.

IMPORTANT

Refer to the SLC 500 Lithium Battery Installation Instructions,
publication

1747-IN515

, for more information on handling,

usage, storage, and disposal of lithium batteries.

ATTENTION

When you connect or disconnect the battery an electrical arc
can occur. This could cause an explosion in hazardous location
installations. Be sure that the area is nonhazardous before
proceeding.
For Safety information on the handling of lithium batteries,
including handling and disposal of leaking batteries, see
Guidelines for Handling Lithium Batteries, publication

AG 5-4

.

Advertising