8 Overview

1758-FLO DataSite controllers

In addition to the features listed in preceding sections, the 1758-FLO DataSite
controllers provide the additional feature of being able to calculate gas flow.
1758-FLO DataSite controllers contain the 1758-FLO flow measurement
algorithm which conforms to the following standards:

• AGA-3 (1992 version)

(1)

orifice metering of natural gas and other

related hydrocarbon fluids;

• AGA-7

(1)

measurement of gas by turbine meters;

• AGA-8

(1)

compressibility factors of natural gas and other related

hydrocarbon gases.

The 1758-FLO controller can be configured by using the DS FloConfig
software. This tool provides functions such as reading and revising parameters,
reading historical data and monitoring measurement results.

Features at a Glance

• Advanced 32-bit processor with embedded real-time multi-task

operating system (RTOS).

• 8 analog inputs (2 with point-to-point HART interface), 2 analog out, 8

discrete inputs, 4 discrete outputs, and 3 pulse inputs.

• Embedded Ethernet, two serial ports (RS232/RS485) and one HART

multi-drop interface; native protocols include Modbus RTU, Modbus
ASCII, and Modbus TCP.

• 6M Flash, 1M RAM, and 32K ferroelectric RAM for long-term storage

of configured parameters.

• HiBeam technology that allows the DataSite controller to act as a web

and event-based data server. HiBeam also has tools for interfacing with
your controller-based data through a standard web browser.

• Conformity to IEC61131-3. Supports LD, FBD, IL, ST and SFC

programming languages.

• Isolation of power supply, signal output and input terminals from the

main control circuit.

• Standard industrial design and DIN rail mounting option, which are

convenient for field installation and configuring interior hardware.

(1)

The 1758-RTU controller does not have AGA-3, AGA-7 or AGA-8 calculations.