Update the controller – Rockwell Automation 1756-Lx_Mx ControlLogix Controller and Memory Board Installation Instructions User Manual
Page 32

32 ControlLogix Controller and Memory Board
Publication
1756-IN101L-EN-P - June 2008
Update the Controller
1. Connect the controller or chassis to the same network as your
workstation.
2. Start ControlFLASH software.
3. Click Next.
4. Select the catalog number of the controller, and click Next.
5. Expand the network until you see the controller.
IMPORTANT
RSLogix 5000 software, version 10.0 or later, lets you update the firmware
of a controller as part of the download sequence. To update the controller,
download your project and follow the prompts of the software.
IMPORTANT
If the required network is not shown, first configure a driver for the
network in RSLinx software.
To expand a network one level, do
one of the following:
• Double-click the network.
• Select the network and
press the
→
key.
• Click the + sign.
Workstation
Linx Gateways, Ethernet
driver
communication module
backplane
controller
−
+
−
−
−
+