Crimp Settings

Table 2 - Settings Matrix for 8-point Indent Crimp Tool with Digital Display

Contact Type

(1)

Locator
Cartridge

(3)

Wire Size, mm

2

(AWG)

(4)

0.1

(27)

0.14

(26)

0.2

(24)

0.24

(23)

0.35

(22)

0.5

(20)

0.75

(19)

0.82

(18)

1.0

(17)

1.3

(16)

1.5

(15)

2.1

(14)

2.5

(13)

3.3

(12)

4.0

(11)

60.001.11

6

F1/

0.71

F2/

0.81

F2/

0.81

F3/

0.91

F4/

0.99

F4/

0.99

F4/

0.99

F5/

1.14

60.003.11

1

F5/

1.14

F5/

1.14

F6/

1.32

F6/

1.32

F6/

1.32

F7/

1.50

F7/

1.50

F7/

1.50

F8/

1.72

60.011.11

6

F1/

0.71

F2/

0.81

F2/

0.81

F3/

0.91

F4/

0.99

F4/

0.99

F4/

0.99

F5/

1.14

60.023.11

1

F3/

0.91

F4/

0.99

F4/

0.99

F5/

1.14

61.004.11

6

F1/

0.71

F2/

0.81

F2/

0.81

F3/

0.91

F4/

0.99

F4/

0.99

F4/

0.99

F5/

1.14

61.009.11

5

F1/

0.71

F2/

0.81

F2/

0.81

F3/

0.91

F4/

0.99

F4/

0.99

F4/

0.99

F5/

1.14

61.010.11

1

F5/

1.14

F5/

1.14

F6/

1.32

F6/

1.32

F6/

1.32

F7/

1.50

F7/

1.50

F7/

1.50

F8/

1.72

61.020.11

3

F1/

0.71

F2/

0.81

F2/

0.81

F3/

0.91

F4/

0.99

F4/

0.99

F4/

0.99

F5/

1.14

61.021.11

2

F5/

1.14

F5/

1.14

F6/

1.32

F6/

1.32

F6/

1.32

F7/

1.50

F7/

1.50

F7/

1.50

F8/

1.72

61.022.11

1

F5/

1.14

F5/

1.14

F6/

1.32

F6/

1.32

F6/

1.32

F7/

1.50

F7/

1.50

F7/

1.50

F8/

1.72

61.023.11

1

F3/

0.91

F4/

0.99

F4/

0.99

F5/

1.14

61.027.11

2

F3/

0.91

F4/

0.99

F4/

0.99

F5/

1.14

Extraction

(2)

Force

(pull test) [N]

Setpoint

12

18

28

32

45

60

85

90

108

135

150

200

230

275

310

Actual Value

>20

>30

>40

>45

>65

>100

>140

>145

>190

>200

>260

>300

>390

>420

>600

(1) The contacts are included in small bags in the connector and extension kits. Match the number on the bag of contacts to the number in the contact type column.
(2) The values serve as reference only and must be verified with a pull test according to BS EN 60352-2, Table 4, using a particular wire.
(3) The contact type determines which locator cartridge to use. Match the contact type number to the locator cartridge number.
(4) Match the wire size and crimp value to an available contact type to determine the locator cartridge. The crimp values are shown in MIL/mm values.