3-1

C

HAPTER

3

Configuring the Drive

This chapter describes how to configure a WebPak 3000 drive.

3.1

Selecting an Application Type

The WebPak 3000 drive can be configured for nine different application types: eight
named applications and Generic. The application types are as follows:

Constant Diameter Speed Regulator

Variable Diameter Speed Regulator

Constant Diameter Current Regulator

Variable Diameter Current Regulator

Constant Diameter Position Regulator

Variable Diameter Position Regulator

Constant Diameter Tension Regulator

Variable Diameter Tension Regulator

Generic

To select an application type:

Step 1. From the File menu, select Application Type, or from the toolbar, click

.

Step 2. A list box will be displayed. When you select an application type, the

application edit view is reset to the first screen in the application edit
sequence.

The application type you select determines which screens are displayed in the
Configuration Setup and Edit view (see figure 3.1). The named application types will
show only the parameters that are pertinent to that application type. If a specific
application type cannot be determined during file open or drive connect, then the
application type defaults to Generic.

The Generic application type is used to display screens which are not tailored toward
any particular application. The generic application screens make all input parameters
available for editing.