5 starting and stopping the drive, 6 monitoring drive indicators – Rockwell Automation WebPak CS Software Version 1.0 User Manual

Page 44

Advertising
background image

7-4

WebPakCS Software V1.0

7.5

Starting and Stopping the Drive

Use the Run, Jog, and Stop/Reset buttons as follows:

7.6

Monitoring Drive Indicators

The Drive Metering box displays five drive indicators for WebPak 3000 drives:

Selected reference

Motor speed

Armature volts

Motor current

Percent load

Each drive metering value is displayed as a visual thermometer-type indicator and as
a numeric value. If the numeric value exceeds the range of the indicator, the indicator
moves slightly beyond the far right line in the indicator grid.

To send this command to the drive:

Press:

Description:

Tension the web

Tension On

Engages the tension loop. The motor will turn
until slack is out of the web, then wait for
Section Run command.

This control is disabled if the WebPakCS
software is not the control source or if

OCL SELECT

(P.817) is set to NONE.

Start

Section Run

Starts the drive. The motor will ramp up to the
selected line speed reference.

This control is disabled if the WebPakCS
software is not the control source.

Jog forward

Jog reverse

Jog Fwd

Jog Rev

The drive will jog while the button is pressed.
Releasing the button sends a stop command
to the drive.

These controls are disabled if the WebPakCS
software is not the control source.

Stop

STOP - Section off

This control is always enabled, regardless of
the control source.

Advertising