Controlling the Drive

7-3

You must select Serial to control the drive using the Drive Control window. If any other
control source is selected, you can only monitor the drive functions displayed in the
Drive Metering window or reset faults and alarms. All of the other drive commands on
the Drive Control screen are disabled.

7.3

Setting the Line Speed Reference

The Line Speed Reference box lets you set the drive reference.

Set the line speed reference by:

moving the scroll bar to change the reference value and automatically send the
value to the drive, or

entering a new value in the edit box and selecting the Set button to send the
reference value to the drive

7.4

Setting the Jog Reference

The Jog Reference box lets you set the jog reference. The valid values are the same
as for the line speed reference. To do this:

Step 1. Click in the Jog reference box and type a new value.

Step 2. Press the Jog Set button.