2. Secure the first hole in the long end of the DC+ bus bar assembly to the

insulated standoff on the right side mounting rail using an M10x16 bolt and
flat and lock washer as shown below.

Verify that the bus bar closest to the front of the drive is in front of the DC+
terminal on the drive and that the connection holes align.

Important: Do not fully tighten this assembly. Final torque must be applied

after all bus bars have been installed.

Top View

Verify bus bar is in front

of DC+ terminal and

holes align

Note: only right side enclosure shown.