8 Installing the Enwatch
Each channel (16 total) has a 3-way header associated with it. These are labeled
with the channel number and “A” or “B.” The three jumper options are:
•
Fitted to position xA
•
Fitted to position xB
•
Not fitted
where x is the channel number 1-16.
LEDs
Four LEDs, as shown in Figure 1.2 on page 4, indicate the status of the
Ethernet communication. These illuminate as described in Table 1.12.
Position
Coupling
x A
ICP
x B
DC Coupled
Not Fitted
AC Coupled
IMPORTANT
The -3dB point of the high-pass coupling for the ICP
interface and AC Coupled configuration is 0.07 Hz.
Table 1.12 LEDs
LED
Description
OB
The Enwatch unit is accessing LAN controller
LK
Communication link is established between Enwatch unit and
network
RX
Data is being received
TX
Data is being transmitted