Connectors – Rockwell Automation 44887-PUB, 44887 Enwatch User Manual
Page 9

Publication GMSI10-UM031C-EN-E - January 2009
Installing the Enwatch 5
Connectors
The Enwatch unit has 11 connectors labeled J1 to J11 as shown in Table 1.1.
The location of the connectors is shown in Figure 1.2 on page 4. The pin
outputs are listed in the following tables.
Table 1.1 Enwatch connectors
Connector
No. of Pins
Function
J1
16
Analog input channels 1–8
J2
16
Analog input channels 9–16
J3
3
External trigger 1 / event 1
J4
3
External trigger 2 / event 2
J5
3
External trigger 3
J6
3
External trigger 4
J7
5
Test points (service use only)
J8
8
Ethernet interface
J9
2
Supply voltage
J10
2
Spare
J11
9
Serial port (RS-232)
Table 1.2 J1 and J2 pin outputs
J1: Analog Inputs 1-8
J2: Analog Inputs 9-16
Signal
Pin No
Signal
Pin No.
CH 1 input
CH 1 ground
1
2
CH 9 input
CH 9 ground
1
2
CH 2 input
CH 2 ground
3
4
CH 10 input
CH 10 ground
3
4
CH 3 input
CH 3 ground
5
6
CH 11 input
CH 11 ground
5
6
CH 4 input
CH 4 ground
7
8
CH 12 input
CH 12 ground
7
8
CH 5 input
CH 5 ground
9
10
CH 13 input
CH 13 ground
9
10
CH 6 input
CH 6 ground
11
12
CH 14 input
CH 14 ground
11
12
CH 7 input
CH 7 ground
13
14
CH 15 input
CH 15 ground
13
14
CH 8 input
CH 8 ground
15
16
CH 16 input
CH 16 ground
15
16