24 Installing the Enwatch

Maximum number of averages that can
be supported

Number of samples required: Lines x 2.56 + lines x 2.56(#avg -1) x (1 -%overlap)
Max number of samples per configuration: 32768
Max number of averages = ((32768 / (lines x 2.56)) - 1) / (1 -%overlap) + 1)

The following table shows the maximum number of averages versus the number of lines and
percent overlap for non-trigger point.

The following table shows the maximum number of averages versus the number of lines and
percent overlap for pre-trigger point.

Signal detection

RMS, Peak, Peak-Peak

Configuration downloading

Route mode configuration downloads to Flash memory
Live mode configuration downloads to RAM

Note: You can reduce number of average or increase percent overlap to reduce amount of
memory used.

Table 1.16 Enwatch measurement capabilities

Product Feature

Capability

Max samples-non trigger points 32768

% overlapping

% overlapping

% overlapping

% overlapping

#lines

0

0.25

0.5

0.75

100

128 170 255 509

200

64

85

127

253

400

32

42 63 125

800

16 21 31 61

1600

8

10

15

29

3200

4

5 7 13

6400

2 2 3 5

12800

1 1 1 1

Max samples-trigger points 16384

% overlapping

% overlapping

% overlapping

% overlapping

#lines

0

0.25

0.5

0.75

100

64 85 127 253

200

32 42 63 125

400

16 21 31

61

800

8 10 15 29

1600

4 5 7 13

3200

2 2 3 5

6400

1 1 1 1

12800

-

-

-

-