Introduction to the controller, Scope of this manual – Rockwell Automation MinPak Plus DC Drive User Manual User Manual

Page 6

Advertising
background image

2:1

2: Introduction to the Controller

Scope of This Manual

This manual familiarizes you with

the MinPak Plus DĆC Controller. It

describes receiving, storage,

application, implementation and

installation procedures and

provides an overview of

specifications and operations.
Read this manual in its entirety

before installing and powering the

Controller. Observe all danger

notes, warning notes, and caution

notes; these precautions point out

potentially hazardous procedures

and conditions. All three types of

precautions are enclosed in a box

to call attention to them.
D A DANGER alerts a person that

high voltage is present that

could result in severe bodily

injury or loss of life.

D A WARNING alerts a person to

potential bodily injury if

procedures are not followed.

D A CAUTION alerts a person that

if procedures are not followed,

damage to, or destruction of

equipment could result.

DANGER

ONLY QUALIFIED ELECTRIĆ

CAL PERSONNEL FAMILIAR

WITH THE CONSTRUCTION

AND OPERATION OF THIS

EQUIPMENT AND THE HAZĆ

ARDS INVOLVED SHOULD INĆ

STALL, ADJUST, OPERATE

AND/OR

SERVICE

THIS

EQUIPMENT. READ AND UNĆ

DERSTAND THIS MANUAL IN

ITS ENTIRETY BEFORE PROĆ

CEEDING. FAILURE TO OBĆ

SERVE THIS PRECAUTION

COULD RESULT IN SEVERE

BODILY INJURY OR LOSS OF

LIFE.

MinPak Plus SingleĆPhase DĆC Controller Specifications

Input Voltage and Frequency Ratings:
Nominal Line Voltage

115 or 230 VAC

. . . . . . . . . . . . . . . . . . . . . .

Number of Phases

Single

. . . . . . . . . . . . . . . . . . . . . . . . .

Voltage Variation

+ 10% of Nominal

. . . . . . . . . . . . . . . . . . . . . . . . . .

Nominal Line Frequency

50 or 60 cycles

. . . . . . . . . . . . . . . . . . . .

Frequency Variation

+ 2 cycles of Nominal

. . . . . . . . . . . . . . . . . . . . . . . .

AĆC Line Fault Ampacity:

Allowable AĆC Line Symmetrical

1,000 or (horsepower dependent)

. . . . . . . . . . . . .

Fault Current (RMS)

5000 amps (with NEC or CEC approved external disconnect)

. . . . . . . . . . . . . . . . . . . . . . . .

(See Table 2Ć1).

AĆC Line KVA:

Maximum Source KVA

(See Table 2Ć1)

. . . . . . . . . . . . . . . . . . . . .

Multiple Drives per Line

Maximum 3 Drives per Line

. . . . . . . . . . . . . . . . . . . . .

Minimum Source KVA

(See Table 2Ć1)

. . . . . . . . . . . . . . . . . . . . . .

DĆC Voltage Ratings:

115 VAC Line:

Armature Voltage

90 VDC

. . . . . . . . . . . . . . . . . . . . . . . .

Field Voltage

50 or 100 VDC

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

230 VAC Line:

Armature Voltage

180 VDC

. . . . . . . . . . . . . . . . . . . . . . . .

Field Voltage

100 or 200 VDC

. . . . . . . . . . . . . . . . . . . . . . . . . . . .