A:16

Figure AĆ19. Zero Minimum Speed Correction

Table AĆ9. Initial/Final Adjustment Settings

Potentiometers

Jumpers

Initial Setting (Factory) Final Setting (User)

MAX. SPD.

Fully CCW (Dot 1)

MIN. SPD

Fully CCW (Dot 1)

ACC.

Fully CCW (Dot 1)

DEC.

Fully CCW (Dot 1)

I LIMIT

150% (Dot 7)

IR COMP

Fully CCW (Dot 1 = 0%)

Feedback

1

A

Current

Scaling

2.5

J4

2

Installed

J5, J6

3

Installed

J7, J8

4

Installed

J9

5

Installed

1> AĆCOMis the standard connection for Armature Feedback; Factory Setting.

CĆCOM is the connection for CEMF if CEMF transformer is installed;CEMF function was replaced

by Armature feedback in Design H".

TĆCOMis the connection for Tachometer Feedback if Tach Feedback Kit is installed.

2> Remove if Local Auto/Man Switch is installed.

3> Remove on 230 Volt units.

4> Remove for Torque Taper.

5> Remove when Reverse Relay (Contactor) Kit is installed.