MinPak Plus

SingleĆPhase DĆC

Controller Description

The Reliance Electric MinPak Plus

SingleĆPhase DĆC Controller is a

fullĆwave power converter without

back rectifier, complete with an

analog current minor loop and an

analog major loop for armature

voltage or speed regulation by

tachometer feedback. The product

line has been setĆup to be sold as

listed in Table 2Ć1.
The Controller is provided, as

standard, in a NEMA Type 4/12

enclosure intended for wall or panel

mounting. It is made up of a chassis

and hinged cover. (Type 4 may be

generally defined as a washĆdown"

design. The enclosure may be

easily converted into a chassisĆonly

type configuration for panel

mounting within a large electrical

enclosure. An optical remote control

station may then be placed on the

larger enclosure's face or some

distance away.
A single power POWER ON/OFF

circuit breaker is standard with each

chassis and is independent of the

cover and faceplate.
For proper operation of the

Controller, it is necessary to use an

Operator's Station. The Operator

Stations allow the tailoring of control

functions for the application.

There are two basic configurations

that may be selected:
D Local Station - station mounted

on Controller Chassis Cover

D Remote Station - station

mounted remotely as a separate

unit

Local Station
Available is a selection of 8

standard Faceplates in order to

configure a controller to a specific

drive application. Refer to Table

2Ć1A. The Faceplate design

maintains the NEMA Type 4/12

rating assuming the Cover is

properly installed.

Table 2Ć1. Controller Model Numbers

Model Number

Optional

Transf.

KVA

Enclosed Chassis

HP

VAC

(3)

AĆC

Amps

(RMS)

DĆC

Arm.

(Volts)

DĆC

Arm.

Amps

Avg.

DĆC

Field

Volts

Amp.

MAX

Power

Supply

Capacity

(2)

MAX

MIN

14C10

14C20

1/4

115

3.5

90

2.5

100

3.0

1000

40.0

0.50

1/3

115

5.2

90

3.7

100

3.0

1000

40.0

0.75

1/2

115

7.0

90

5.0

100

3.0

1000

40.0

1.50

3/4

115

10.5

90

7.5

100

3.0

1000

40.0

1.50

14C11

14C21

1/2

230

3.5

180

2.5

200

3.0

1000

40.0

1.50

3/4

230

5.2

180

3.7

200

3.0

1000

40.0

1.50

1

230

7.0

180

5.0

200

3.0

1000

40.0

2.00

1 1/2

230

10.5

180

7.5

200

3.0

5000

40.0

3.00

14C12

14C22

2

230

14.0

180

10.0

200

3.0

1

5000

40.0

5.00

3

230

21.0

180

15.0

200

3.0

1

5000

40.0

10.0

14C13

14C23

5

230

35.0

180

25.0

200

3.0

1

5000

40.0

10.0

1

Standard

2

Maximum permissible available symmetrical RMSfault current (amperes) with NEC or CEC external approved disconnect.

3

Does not include current required for Field Supply (if used).

Advertising