Parameters 40…49—Function Settings (read only)

Function Switch Value Module 1…10

These parameters indicate the actual rotary switch settings on MSR320 Input Modules. There is one parameter for each
module. Parameter 40 is the input module closest to the base module. These values should be compared to their respective
values in nonvolatile memory (Parameters 50…59). If the values are not the same, the MSR300 system will be in a faulted state.

No value = The module is a muting lamp module.

Reserved = The module does not exist in the system.

Parameters 50…59—Nonvolatile (EEPROM) Function Settings (read only)

Function NV Value Module 1…10

These parameters indicate the rotary switch settings that are stored in nonvolatile memory in the base module. There is one
parameter for each module. Parameter 50 is the input module closest to the base module. These should be compared to their
respective values in actual settings (Parameters 40…49). If the values are not the same, the MSR300 system will be in a faulted
state.

No value = The module is a muting lamp module.

Reserved = The module does not exist in the system.

0.
1.
2.
3.
4.
5.
6.
7.
8.
9.

Reserved
One-Channel Emergency Stop
Two-Channel Emergency Stop, Safety Mat
Three-Channel Emergency Stop
Two-Channel Safety Gate w/ Start-Up Test
Two-Channel Safety Gate w/o Start-Up Test
Two-Channel Light Curtains
Two-Hand Control
Input 1: Two-Channel Emergency Stop, Input 2: Light Curtain (2 NC, 2 OSSD)
Input 1: Two-Channel Safety Gate, Input 2: Light Curtain (1 NO & 1 NC, 2 OSSD)

0.
1.
2.
3.
4.
5.
6.
7.
8.
9.

Reserved
One-Channel Emergency Stop
Two-Channel Emergency Stop, Safety Mat
Three-Channel Emergency Stop
Two-Channel Safety Gate w/ Start-Up Test
Two-Channel Safety Gate w/o Start-Up Test
Two-Channel Light Curtains
Two-Hand Control
Input 1: Two-Channel Emergency Stop, Input 2: Light Curtain (2 NC, 2 OSSD)
Input 1: Two-Channel Safety Gate, Input 2: Light Curtain (1 NO & 1 NC, 2 OSSD)