HOW TO SET THE FAN SPEED

Display Section

All indicators are shown in the right and the lower figures for the
explanation.
Only selected contents are display in actual operation.
• When turning on the leakage breaker at the first time 3

minutes later, [SET DATA] flashes about for 1 minute on the
display part of the remote controller. While this display is
flashing, the model is being automatically confirmed.
Accordingly, wait for 1 minute after [SET DATA] display has
disappeared, and then use the remote controller.

1

Transmitting indication
Displayed while operating the switches of
the remote controller.

2

Mode display
The selected operation mode is displayed.

3

Fan mode select display
The selected fan mode is displayed.

(AUTO)

(HIGH)

(MED.)

(LOW)

4

Filter display

If “FILTER

” is displayed, clean the air

filter.

5

CHECK display
Displayed while the protective device
works or a trouble occurs.

6

Set up temperature display
The selected set up temp. is displayed.

7

Flap position display

8

SWING display
Displayed during up/down movement of
the flap.

9

Timer time display
Time of the timer is displayed.
(When a trouble occurs, the check code is
displayed.)

10

Timer SETIN setup display
When pushing the Timer SET button,
the display of the timer is selected in
order of [OFF]

[OFF] repeat OFF timer

[ON]

No display.

ADR

1

10

2

3

4

5

6

8

7

9

ADR

ACL

SENSOR

SET

CL

ADR

Display
section

Operation
section

Operation Section

Push each button to select a desired operation.
• The details of the operation needs to be set up once, afterward, the air conditioner can be

used by pushing

button only.

1

Operation select button
Selects desired operation mode.

2

Fan mode select button
Selects a fan mode.

3

Timer set button
TIMER SET button is used when the
timer is set up.

4

Check button
CHECK button is used for check
operation. During normal operation, do
not use this button.

5

Temperature set button
Adjusts required room temperature.
Set required set temperature by
pushing

or

.

6

Start/Stop button
When the button is pushed, operation starts,
and it stops by pushing the button again.
When the operation stops, the operation lamp
and all displays disappear.

7

Filter reset button

Resets (Erases) “FILTER

” display.

OPTION :

Remote controller sensor
Usually the TEMP. sensor of the indoor unit
measured a temperature. A temperature around
the remote controller can also be measured.
For details, contact the dealer from which you
have purchased the air conditioner.

SET

ACL

SENSOR

CL

ADR

7

2

1

4

3

5

6

RBC-AX22CE