How to set the room temperature sensor

• The room temperature sensors are equipped in the indoor unit and the wireless remote controller.

One of two sensors works.

• The room temperature sensor is set to the indoor unit side at the shipment from the factory.

To select the sensor in the remote controller, push the SENSOR button (Right figure) inside of the
remote controller cover and check “Main sensor” disappears from LCD.

NOTE :
If the room temperature data from the remote controller is not
transmitted to the unit for 10 minutes or more, the sensor at indoor
unit side is automatically selected even if the sensor at the remote
controller side is selected.
Fix the remote controller toward the unit as possible.

How to set the address switch

• When the multiple sensors are installed in the same room, an address can be set to prevent cross

communication.

• When replacing the battery and pushing SET button, the address of the remote controller becomes

[ALL] and the sensor is enabled to receive signal regardless of setting of address switch of the
operation section.

• For selecting of the

remote controller
address, refer to
Owner’s Manual.

• Change the address of

the sensor by removing
screws of P.C. board
cover of the sensor
unit. After then, fix the
cover with screws
using a clamp.

Slide switch

• Check the slide switch in the battery

box of the remote controller is set to
[S] / [A] at shipment from the factory.
Do not change the setting.

Self-diagnosis table and measures

Lamp indication

No indication even if
the remote controller
is operated.

Cause

Power supply is not
turned on.
Miscabling between
sensor unit and indoor
unit

Defective connection
between sensor unit
and indoor unit

Miscabling or defective
connection between
indoor and outdoor
units

Protective device of
outdoor unit works.

Protective device of
indoor unit works.

Measures

Che

ck cable

connection
and correct it.

Check
outdoor unit.

Check
indoor unit.

Lamp indication of sensor

: Goes off
: Flash

(0.5-sec. interval)

SET

ACL

SENSOR

CL

ADR

Sensor
button

S001

4–6

S002

3

6

2

5

1

4

Address select

Address

S002

3

6

2

5

1

4

Address

S002

3

6

2

5

1

4

Address

S001

4–6

Address select

S001

4–6

Address select

Display of
remote
controller
address

Address
switch
position of
sensor

* Address switch

of sensor unit
can be set any
position.

Address

Address

Address

Address

1–3

1–3

1–3

S K N

A H C

Select of operation
mode set to A.

Select of flap
indication set to S.

A H C

S K N

Flashes alternatively

Flashes alternatively

How to perform cabling of sensor units

Connection diagram

Connection
• Connect the cables out of the sensor unit to

the terminal block for remote controller cabling
of the indoor unit. (There is no polarity.)

Requirement

The control by two remote controllers is enabled by installing the wireless remote controller with the
wired remote controller for an indoor unit.
(Max. 2 remote controllers of wireless or wired are installable.)

“2-remote controllers” controlling means that one or multiple units are operated by the multiple
remote controllers.

NOTES :
1. Upon confirmation of the terminal numbers of the indoor unit, connect the remote controller cables

without miscabling. (If applied AC 220–240 Volt, damage the unit.)

2. The multiple wireless remote controller kits cannot concurrently be used for an indoor unit.
3. When installing simultaneously the wireless remote controller with the wired remote controller, set

one of them as the sub remote controller.
• When setting the wired remote controller as the sub, exchange the address connector at the rear

of P.C. board of wired remote controller from master to sub remote controller.

• When setting the wireless remote controller as the sub, turn No.3 of DIP switch [S003] on P.C.

board of wireless remote controller sensor unit from OFF to ON.

To operate an indoor unit by 2 remote controllers

*

The indoor unit is operated if
either wireless or wired remote
controller is set as master or
sub remote controller.
(Total cable length: Within 400m)

To operate a group control of multiple indoor units by 2 remote controllers

*

Master and Sub remote
controllers are operable even
if they are installed to any
indoor unit.
(Total cable length: Within 200m)

CN001

2P White

Indoor unit

Sensor unit P.C. board

Terminal block for
remote controller
cabling

White

Black

Earth

Wireless

remote controller kit

(Master)

CN1

Wired

remote controller

(Sub)

2

1

(Sold separately)

(Sold separately)

Terminal block for
remote controller cable

Remote controller cable
(Procured locally)
(0.5 to 2mm²)

Indoor unit

2

1

Sensor
unit

Earth

Earth

Earth

(Sold

separately)

(Sold

separately)

Terminal block

for remote

controller

cable

Remote controller inter-unit

cable for group control

(Procured locally)

(0.5 to 2mm²)

2

1

Wired

remote controller

(Sub)

Wireless

remote controller kit

(Master)

CN1

2

1

Indoor unit

No.1

Indoor unit

No.2

Indoor unit

No.3

Earth

Indoor unit

No.N

Sensor

unit

RBC-AX22CE