WARNING: Synchronization

In situations where multiple systems are mounted closely together, or where a secondary emitter is in view
(within ±5°), within range of an adjacent receiver; a receiver may synchronize to the signal from the wrong
emitter, reducing the safety function of the light screen.

WARNING: Multiple Pairs of Sensors

Do not connect multiple pairs of sensors to one Interface Module (for example, IM-T-9A/-11A) or otherwise
parallel OSSD outputs.

Connection of multiple OSSD safety outputs to a single device can result in an increased risk of
harm, and is prohibited.

Mounting System Components

Overview of Emitter/Receiver Mounting Hardware

Mounting Hardware

The EZ-SCREEN standard end-cap mounting bracket hardware is
supplied with each emitter and receiver. Brackets are designed to
mount directly to MSA Series stands using the hardware with the
supplied stands.