Interface Modules

Provide forced-guided, mechanically-linked relay (safety) outputs for the EZ-SCREEN System. See Banner data sheet p/n 62822 for
more information.

Interface module (3 N.O. redundant-output 6 amp contacts)

IM-T-9A

Interface module (2 N.O. redundant-output 6 amp contacts, plus 1 N.C. auxiliary contact)

IM-T-11A

Contactors

If used, two contactors per EZ-SCREEN Type 2 System are required.

10 amp positive-guided contactor 3 N.O., 1 N.C.

11-BG00-31-D-024

18 amp positive-guided contactor 3 N.O., 1 N.C. (N.C. contact rated @ 10 amps)

BF1801L024

Lens Shield

Constructed of 1.5 mm clear polycarbonate; attach to sensor using supplied adhesive-backed Neoprene foam strips.

NOTE: The total range decreases by approximately 10% per shield.

Sensor Defined Area Height

Lens Shield Model

Lens Shield Length

150 mm

LSS-150

210 mm (8.3")

300 mm

LSS-300

360 mm (14.2")

450 mm

LSS-450

510 mm (20.1")

600 mm

LSS-600

660 mm (26.0")

750 mm

LSS-750

810 mm (31.9")

900 mm

LSS-900

959 mm (37.8")

1050 mm

LSS-1050

1109 mm (43.7")

1200 mm

LSS-1200

1259 mm (49.6")

1350 mm

LSS-1350

1409 mm (55.5")

1500 mm

LSS-1500

1558 mm (61.3")

1650 mm

LSS-1650

1708 mm (67.2")

1800 mm

LSS-1800

1858 mm (73.1")