Verifying Initial Emitter/Receiver Alignment

As you mount the sensors, make sure that

• The emitter and receiver are directly opposite each other.
• Nothing is interrupting the defined area (marked on the sensors).
• The defined area is the same distance from a common reference plane for each sensor.
• The emitter and receiver are in the same plane and are level/plumb and square to each other (vertical, horizontal, or inclined at the

same angle).

Angled or Horizontal Installations

Vertical Installations

Verify that the

• Distance X at the emitter and receiver are equal.
• Distance Y at the emitter and receiver are equal.
• Distance Z at the emitter and receiver are equal from parallel

surfaces.

• Vertical face (that is, the lens) is level/plumb.
• Defined area is square. Check diagonal measurements if

possible; see Vertical Installations, at right.

Verify that the

• Distance X at the emitter and receiver are equal.
• Both sensors are level/plumb (check both the Distance Z at

the emitter and receiver are equal from side and face).

• Defined area is square. Check diagonal measurements if

possible (Diagonal A = Diagonal B).

Level Surface

X

X

Emitter

Receiver

level

level

Y

Y

Z

Z

Level Surface

A

B

level

level

X

X

NOTE: Make sure that the emitter and
receiver are not tilted front-to-back or
side-to-side as shown.

EZ-SCREEN® Type 2 Light Screen Instruction Manual

122452 rev. B

www.bannerengineering.com - tel: 763-544-3164