Initial checkout procedure – Banner EZ-SCREEN­ Safety Light Curtain Systems User Manual

Page 28

Advertising
background image

The other wires are for an optional hookup that allows for parallel connection (color-for-color) to the receiver cable. This optional hookup
provides for sensor interchangeability (or swapability) that facilitates installing either sensor at either QD connection. Besides providing
similar cabling, this wiring scheme is advantageous during installation, wiring, and troubleshooting.

Individual Cordsets

Splitter Cordsets

EZ-SCREEN Type 2

Bn
Or/Bk
Or

Wh
Bk

Bu
Gn/Ye
Vi

+24V dc

C

n.c.

n.c.
OSSD2
OSSD1

0V dc
Ground
Reset/Test & EDM

A

B

D

C

A

B

Key

Description

A

Emitter

B

Receiver

C

QDE-8..D Cordsets

Key

Description

A

Emitter

B

Receiver

C

DEE2R.. Cordsets

D

CSB.. Cordsets

Initial Checkout Procedure

The initial checkout procedure must be performed by a Qualified Person. It must be performed only after configuring the system and after
connecting the emitter and receiver.

The procedure is performed on two occasions:

• To ensure proper installation when the System is first installed
• To ensure proper System function whenever any maintenance or modification is performed on the System or on the machinery being

guarded by the System.

EZ-SCREEN® Type 2 Light Screen Instruction Manual

28

www.bannerengineering.com - tel: 763-544-3164

122452 rev. B

Advertising
This manual is related to the following products: