4. Watch both the emitter and the receiver LED indicators to determine light screen alignment status.

Power/Fault LED (Green)

Figure 10. Emitter Status Indicators

Alignment LEDs

(Yellow)

Status Blocked LED (Red)

Status Clear LED (Green)

Figure 11. Receiver Status Indicators

Lockout Condition

On the emitter, the green Power indicator is flashing or on the receiver, the red Status Blocked indicator is flashing. See

Troubleshooting and Lockout Conditions

on page 47 for diagnostic information.

Normal Operating Mode

On the emitter, the green Power indicator is ON.

Test Mode

On the receiver, the red Status Blocked indicator is ON and the green Status Clear indicator is flashing. Test input
open.

Test Mode, input fault

On the receiver, the red Status Blocked indicator is ON and the green Status Clear indicator is ON. Test input open at
power-up.

Latch Condition, all optical beams clear

On the receiver, the red Status Blocked indicator is ON and both yellow Alignment indicators are flashing. For Latch
Output receivers, the outputs are ON only when all beams are clear and after a manual reset. If a reset routine can
cause a Clear (Run) condition, optimize the alignment as described in

Optical Alignment

on page 31. If a Clear (Run)

condition can not be achieved, see “Blocked condition” below.

Clear (Run) Condition

On the receiver, the green Status Clear indicator is ON Green, and both yellow Alignment indicators are ON. To opti-
mize alignment and maximize excess gain, slightly loosen the four sensor mounting screws and rotate one sensor left
and right, noting the positions where the red Status Blocked indicator turns ON; repeat with the other sensor (see

Optical Alignment

on page 31). Center each sensor between those two positions and tighten the end cap mounting

screws, making sure to maintain the positioning as the screws are tightened. The sensor lenses should directly face
each other. Proceed to Trip Test (

Trip Test

on page 32) once optimum optical alignment is verified.

A Blocked Condition

On the receiver, the red Status Blocked indicator is ON, and both yellow Alignment indicators are ON or OFF. To reme-
dy, perform the

Optical Alignment

on page 31 procedure.