Generic wiring to fsds (manual reset), Ring). see, Ez-screen generic fsds wiring – Banner EZ-SCREEN­ Safety Light Curtain Systems User Manual

Page 41: Ossd outputs. refer to

Advertising
background image

Generic Wiring to FSDs (manual reset)

+24V dc

0V dc

Receiver

8-pin male Euro-style

face view

*

Bn (Pin #1)

Gn/Ye (#7)

Bu (#6)

Bk (#5)

Wh (#4)

Vi (#8)

Or (#3)

Or/Bk (#2)

+24V dc

Ground

0V dc

OSSD1

OSSD2

Reset/Test

Manual Test

or Reset

(Latch or Lockout)

Automatic

Test

FSD

Monitoring

Circuit

n.c.

n.c.

FSD

2

FSD

1

Single-Channel

Safety Stop

Circuit

Dual-Channel

Safety Stop

Circuit

NOTE: Do not exceed OSSD maximum load
capacitance specification.

*See

Single-Ended (Machine Interface) Cordsets

on page 57 for available cordsets

NOTE: Pins 2 and 3 are not connected, or are connected in parallel to the same color wire from the emitter
cordset and properly terminated.