Banner U-GAGE T30UX Ultrasonic Sensors User Manual

Page 4

Advertising
background image

Output OFF

Output ON

Output OFF

Minimum

Limit

Maximum

Limit

Output ON

Output ON

Output OFF

Minimum

Limit

Maximum

Limit

Normally Closed Operation

Normally Open Operation

Figure 2. Teaching independent minimum and maximum limits

Push Button

0.04 sec. < “click” < 0.8 sec.

Remote Line

0.04 sec. < T < 0.8 sec.

Procedure

Result

Procedure

Result

TEACH
Mode

Push and hold the
Discrete push button
longer than 2 sec-
onds

Power LED: OFF
Output LED: ON

No action required; sensor is ready
for first limit teach

None

Teach First
Limit

Position the target for the first
limit (120 second time out)

Signal LED: Must be
ON Red or Flashing
Red

3

Position the target for the first limit

Signal LED: Must be
ON Red or Flashing
Red

3

“Click” the Discrete
push button

Teach Accepted
Power LED:
OFF
Output LED: Flashing
Teach Not Accepted
Output LED:
ON

Single-pulse the remote line

T

Teach Accepted
Power LED:
OFF
Output LED: Flashing
Teach Not Accepted
Power LED:
ON

Teach Sec-
ond Limit

Position the target for the sec-
ond limit (no time out)

Signal LED: Must be
ON Red or Flashing
Red

Position the target for the second
limit (no time out)

Signal LED: Must be
ON Red or Flashing
Red

“Click” the Discrete
push button

Teach Accepted
Output LED:
ON or
OFF, depending on
NO or NC Mode
Power LED: ON
Teach Not Accepted
Output LED:
Flashing
Power LED: OFF

Single-pulse the remote line

T

Teach Accepted
Output LED:
ON or
OFF, depending on
NO or NC Mode
Power LED: ON
Teach Not Accepted
Output LED:
Flashing
Power LED: OFF

3

Sensor will not Teach or indicate “Teach Not Accepted” when there is no signal present (Signal LED Red or Flashing Red)