Teaching Limits Using the Auto-Window Feature

Teaching the same limit twice automatically centers a window on the taught position (see

Figure 4. Window Size

on page 5 for window

sizes).
General Notes on Teaching

• The sensor will return to RUN mode if the TEACH condition is not registered within 120 seconds after the initial 2 second hold on the

Discrete push button.

• To exit TEACH mode without saving any changes, press and hold the Discrete push button or remote line longer than 2 seconds

(before teaching the second limit). The sensor will revert to the last saved limits.

• After the first limit is taught, the sensor will remain in TEACH mode until the TEACH sequence is finished or exited by a 2 second hold

on the Discrete push button or remote line.

Output OFF

Output ON

Output OFF

Position

Position

Position

Taught Position

Output ON

Output ON

Output OFF

Taught Position

Normally Closed Operation

Normally Open Operation

Position

Figure 3. Using the Auto-Window feature for teaching each

output

Models

Window

"A" suffix

± 10 mm (0.4 in)

"B" suffix

± 20 mm (0.8 in)

"C" suffix

± 30 mm (1.2 in)

Figure 4. Window Size

Push Button

0.04 sec. < “click” < 0.8 sec.

Remote Line

0.04 sec. < T < 0.8 sec.

Procedure

Result

Procedure

Result

TEACH
Mode

Push and hold the
Discrete push button
longer than 2 sec-
onds

Power LED: OFF
Output LED: ON

No action required; sensor is ready
for first limit teach

None

Teach First
Limit

Position the target for the cen-
ter of window (120 second time
out)

Signal LED: Must be
ON Red or Flashing
Red

4

Position the target for the center of
window

Signal LED: Must be
ON Red or Flashing
Red

4

“Click” the Discrete
push button

Teach Accepted
Power LED: OFF
Output LED: Flashing
Teach Not Accepted
Output LED: ON

Single-pulse the remote line

T

Teach Accepted
Power LED: OFF
Output LED: Flashing
Teach Not Accepted
Output LED: ON

Re-Teach
Limit

Without moving the
target, “click” the Dis-
crete push button
again

Teach Accepted
Output LED: ON or
OFF, depending on
NO or NC Mode

Without moving the target, single-
pulse the remote line again

T

Teach Accepted
Output LED: ON or
OFF, depending on NO
or NC Mode

4

Sensor will not Teach or indicate “Teach Not Accepted” when there is no signal present (Signal LED Red or Flashing Red)

U-GAGE® T30UX Series with Discrete Output

P/N 138381_web
Rev. G

www.bannerengineering.com - tel: 763-544-3164

5