Remote line teach – Banner U-GAGE T30UX Ultrasonic Sensors User Manual

Page 6

Advertising
background image

Push Button

0.04 sec. < “click” < 0.8 sec.

Remote Line

0.04 sec. < T < 0.8 sec.

Procedure

Result

Procedure

Result

Power LED: ON
Teach Not Accepted
Output LED: Flashing
Power LED: OFF

Power LED: ON
Teach Not Accepted
Output LED: Flashing
Power LED: OFF

Output OFF

Output ON

Taught Position

(background surface)

Near

Range

Sensor

Output

ON

Sensor

Output

OFF

Any object in this area will switch
the output, whether or not the object
returns a good signal to the sensor.

Sensing Distance

Figure 5. An application for the Auto-Window feature (retroreflective mode)

Remote Line TEACH

General Notes

• Run Mode is the sensor’s normal operating condition
• The duration of each Pulse is defined as “T”: 0.04 < T < 0.8 s

T

• A Hold will exit TEACH MODE and return to Run Mode with previously saved changes. The duration of a Hold is: T > 2 s
• A Timeout will occur if a condition is not registered within 120 seconds, causing the sensor to return to Run Mode (during sensor

configuration only)

• Sensor configuration user feedback shown on Green LED. See flowchart.
• The Red Signal LED will be ON whenever the target is in view.

U-GAGE® T30UX Series with Discrete Output

6

www.bannerengineering.com - tel: 763-544-3164

P/N 138381_web

Rev. G

Advertising