Ocv tool and the remote command channel, Rcc return values – Banner PresencePLUS BCR 1.3 Series User Manual

Page 61

Advertising
background image

Description

Syntax

Sets the specified tool operand, if it is a
constant. Value should be a quoted string (see

set stringtool tool_name|tool_number operand_1|operand_2

Character Strings 6.2.2.6.1 Character Strings

on page 248).

Gets the value of the specified tool operand, if
it is a constant.

get stringtool tool_name|tool_number operand_1|operand_2

OCV Tool and the Remote Command Channel

Commands

Description

Syntax

Sets the expected string, if it is a constant. The
Value should be a quoted string containing

set ocvtool tool_name|tool_number exp_string value|

printable ASCII characters (see

Character

Strings 6.2.2.6.1 Character Strings

on page

248).

Gets the value of the exptected string.

get ocvtool tool_name|tool_number exp_string

RCC Return Values

RCC return values are numeric, and are listed below:

• 0 - command accepted. This return code is generated when a valid SET, GET, and EXEC command

has been completely handled by the sensor. It may be followed by a command-specific return value
or a completion code.

If the frame tag is enabled, the current frame number will be returned instead of 0 as command acceptance
indicator.

• -100 - Invalid command entered by the user.
• Trigger and Product Change error codes:

• -201 - Product change command attempted in the middle of the inspection
• -202 – Trigger command attempted in the middle of product change
• -203 – Trigger command is attempted when the inspection is not executing (sensor is idle)
• -204 – Specified inspection slot is out of range
• -205 – Trigger command attempted in the middle of the inspection
• -206 – Product change command attempted in the middle of a product change
• -207 – Product change command attempted while the sensor is in the Teach mode
• -208 – Product change attempted when the GUI is connected, and the inspection is not executing

• Comm tool error codes

• -301 – get/set tool command attempted while the inspection is not executing
• -302 – get command issued before inspection is triggered for the first time – tool results unavailable
• -303 – get/set tool command attempted in the middle of the inspection
• -304 – get/set tool command attempted in the middle of the product change
• -305 – Tool specified in get/set command not found in the inspection

61

Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com

Tel: 763.544.3164

P/N 000000