Description

Strobe Width Option

The strobe output never becomes active (light off).

Off

The strobe output remains active (light on).

On

The strobe output is active only while the sensor is
acquiring an image. This is the default.

Exposure Duration

Sets the duration for active strobe output from the
initial valid trigger (minimum pulse width has been

Time Duration

satisfied) to the end of the duration. The range is from
0 to 4,000 ms.

6.4.2 Level

Active Low -- When given a 0V dc signal, it turns on. This is the default.
Active High -- When given a +5V dc signal, it turns on.

6.5 Units Tab

Use the Units tab to scale pixels to Engineering units (inches, millimeters, centimeters, etc.) as shown in Units
tab shown below. To scale pixels, folow the instruction

Units Tab