L-GAGE® LT7 Long-Range Time-of-Flight Sensor

Command

Data to LT7*

Data from LT7

Meaning

GSI

Get Error Status

0: No error

1: Error
Bit 7: Transmitter faulty

Bit 6: Receiver blinded or faulty

Bit 5: Temperature warning: T < -10°C or T > +70°C

Bit 4: Target out of range or transmitter faulty

Bit 3: Temperature error: T > +85°C

Bit 2: Supply voltage too low

Bit 1: PLL unlocked

Bit 0: Not used

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

X

X

X

X

X

X

X

X

GTE

±xxx

Get Temperature

Internal temperature in °C

GVE

LT7 $Revision x.xx$

Get Version

Software version is displayed

GCM

All available commands

Help Command/Get Commands

All available commands are displayed in text format

ICM

0, 1

ACK

Input Continuous Measurement Mode

0: Continuous measurement output

1: Output of single measurement values

IDO

Input desired value

ACK

Input Offset Setting (All Outputs)

Up to 12,000 mm (plus or minus) or 480.00" (plus or minus)*

IVL

0, 1

ACK

Enable Visible Laser

0: Pilot laser OFF

1: Pilot laser ON

ISB

0, 1

ACK

Input Stand-by

0: Operation

1: Stand-by

ESM

<meas. value>

Trigger/Execute Single Measurement

Request for measured value with single measurement output

EPW

ACK

Write Parameter Page/Execute Parameter Write

Parameters are stored

Discrete Output Q1

IH1

000.. 254

or

000.. 999

ACK

Set Discrete Q1 Hysteresis

0 - 254 mm or

0" - 9.99"

IL1

Input desired limit value (not

including Offset)

ACK

Input Discrete Q1 Limit 1

0 - 12,000 mm or 0" - 480.00"*

Selected Offset value will be applied to this limit

IL4

Input desired limit value (not

including Offset)

ACK

Input Discrete Q1 Limit 2

0 - 12,000 mm or 0" - 480.00"*

Selected Offset value will be applied to this limit

IM1

0, 1, 2

ACK

Discrete Output Q1 Mode

0: Inactive

1: 1 switching point

2: 2 switching points

IN1

0, 1

ACK

Invert Discrete Output Q1

0: Q

1: Q inverted

*Decimal point and comma are “imaginary.” Do not input commas or periods in data (e.g., 12000 for mm or 48000 for inches).