Ssi-compatible interface, L-gage® lt7 long-range time-of-flight sensor – Banner L-GAGE LT7 Series User Manual

Page 16

Advertising
background image

L-GAGE® LT7 Long-Range Time-of-Flight Sensor

Banner Engineering Corp. • Minneapolis, MN U.S.A

www.bannerengineering.com • Tel: 763.544.3164

16

P/N 120244 Rev. B

SSI-Compatible Interface

T

Tv

Gn

G1

G0

Gn-1

Tm

SSI Data

Clock

Figure 11. SSI-compatible interface timing

T = Duration of clock signal,

minimum 2 µSec = 500 kHz, max. 13 µSec = 77 kHz

Tv = Delay time max. 360 ns
Tm = Minimum time between last rising edge and reloading

of SSI approx. 24 µSec.

Gn = MSB (here Gray Code)
24 bit transmission: G1 = second LSB, G0 = LSB
24+E transmission: G1 = LSB, G0 = Error bit
25 bit transmission: G1 = second LSB, G0 = LSB

NOTE: With SSI-compatible transmission, data updates in synchronization with the readout

cycle. The data is as up-to-date as the time interval between two readouts. An

intermittent readout is therefore recommended. After a longer readout interval, the data

contents of the first readout can be “out-of-date” and should be ignored.

Command

Data to LT7

Data from LT7

Meaning

Discrete Output Q2

IH2

000.. 254

or

000.. 999

ACK

Set Discrete Q2 Hysteresis

0 - 254 mm or

0" - 9.99"

IL2

Input desired limit value (not

including Offset)

ACK

Input Discrete Q2 Limit 1

0 - 12,000 mm or 0" - 480.00"*

Selected Offset value will be applied to this limit

IL5

Input desired limit value (not

including Offset)

ACK

Input Discrete Q2 Limit 2

0 - 12,000 mm or 0" - 480.00"*

Selected Offset value will be applied to this limit

IM2

0, 1, 2

ACK

Discrete Output Q2 Mode

0: Inactive

1: 1 switching point

2: 2 switching points

IN2

0, 1

ACK

Invert Discrete Output Q2

0: Q

1: Q inverted

Analog Output QA (Diffuse sensor models only)

IL3

Input desired limit value (not

including Offset)

ACK

Input Analog QA Limit 1

0 - 12,000 mm or 0" - 480.00"*

Selected Offset value will be applied to this limit

IL6

Input desired limit value (not

including Offset)

ACK

Input Analog QA Limit 2

0 - 12,000 mm or 0" - 480.00"*

Selected Offset value will be applied to this limit

INA

0, 1

ACK

Invert Analog Output QA

0: Q

1: Q inverted

*Decimal point and comma are “imaginary.” Do not input commas or periods in data (e.g., 12000 for mm or 48000 for inches).

Advertising