Dimensions, L-gage® lt7 long-range time-of-flight sensor, Class 2 (visible pilot laser) – Banner L-GAGE LT7 Series User Manual

Page 19: Class 1 (infrared sensing laser), Certifications

Advertising
background image

P/N 120244 Rev. B

19

Banner Engineering Corp. • Minneapolis, MN U.S.A

www.bannerengineering.com • Tel: 763.544.3164

L-GAGE® LT7 Long-Range Time-of-Flight Sensor

Specifications, cont’d

Description of Laser Classes

Class 2 (Visible Pilot Laser)

Lasers that emit visible radiation in the wavelength

range from 400 nm to 700 nm

where eye protection is normally afforded by

aversion responses, including the blink reflex. This

reaction may be expected to

provide adequate protection under reasonably

foreseeable conditions of operation, including the

use of optical instruments for intrabeam viewing.
Reference 60825-1 Amend. 2 © IEC:2001(E),

section 8.2.

Class 1 (Infrared Sensing Laser)

Lasers that are safe under reasonably foreseeable

conditions of operation, including the use of optical

instruments for intrabeam viewing.
Reference 60825-1 Amend. 2 © IEC:2001(E),

section 8.2.

Operating Mode
Laser Class 1

Setup Mode
Laser Class 2
Do not stare into beam

Vibration/Shock

EN 60947-5-2

Application Notes

• All specifications are based on the specified surface at constant ambient conditions and

following a minimum operating time of 15 minutes.

• For best accuracy, allow a 15-minute warmup before programming or operating
Crosstalk avoidance: Light spots must be separated by at least 200 mm.
• Also see page 12 for target orientation notes.

Certifications

OUTPUT1

OUTPUT2

ALARM

POWER

ESC

Operating Mode
Laser Class 1

Setup Mode
Laser Class 2
Do not stare into beam

(Infrared)

(Visible - Red)

Operating Mode
Laser Class 1

Setup Mode
Laser Class 2
Do not stare into beam

(Infrared)

(Visible - Red)

wh

TX + / SSI: Data +

bn

Output 1 (PNP)

gn

RX + / SSI: Clock +

ye

Analog Output: 4 - 20mA

gy

Alarm 1 Output (PNP)

pk

Alarm 2 Output (PNP)

rd

18 - 30V dc

bk

RX - / SSI: Clock -

vt

N/C

gy/pk

TX - / SSI: Data -

rd/bu

Output 2 (PNP)

bu

Gnd

LT7PIDQ

bannerengineering.com

bannerengineering.com

Class 1

L - GAGE

TM

wh

TX + / SSI: Data +

bn

Output 1 (PNP)

gn

RX + / SSI: Clock +

ye

Analog Output: 4 - 20mA

gy

Alarm 1 Output (PNP)

pk

Alarm 2 Output (PNP)

rd

18 - 30V dc

bk

RX - / SSI: Clock -

vt

N/C

gy/pk

TX - / SSI: Data -

rd/bu

Output 2 (PNP)

bu

Gnd

LT7PIDQ

bannerengineering.com

bannerengineering.com

Class 1

L - GAGE

TM

42.0 mm

1.65"

93.0 mm

3.66"

95.0 mm

3.74"

42.8 mm

1.68"

42.0 mm

1.65"

81.5 mm

3.21"

5.75 mm

0.23"

Ø 5.7 mm

0.22"

19.75 mm

0.78"

M5 Threaded

52.0 mm

2.05"

24.0 mm

0.94"

27.5 mm

1.08"

Emitter

10 mm x 5 mm

Dimensions