4 control mode selection, Control module configuration – Banner A-GAGE MINI-ARRAY Series User Manual

Page 19

Advertising
background image

Control Module Configuration

19

Banner Engineering Corp. • Minneapolis, U.S.A.

Website: http://www.baneng.com • Tel: 888.373.6767

4.4 Control Mode Selection

The control mode determines the method used to control scanning of the light screen

array. Choose from three scan control modes:

• Continuous Scan mode (the Factory default setting),

• Host Command mode, and

• Gate mode

In Continuous Scan Mode, the control module begins a new scan as soon as it

updates the outputs from the previous scan. This is the fastest scan control method; it

is used when continuous updating of the outputs is acceptable.

Host Mode allows the user, with a DeviceNet connection, to direct the MINI-ARRAY

System to scan on command.

Gate Mode activates an optically isolated external Gate input between terminals 11 (+)

and 12 (-) of the control module. The Gate input has impedance of 7.5 kΩ and accepts

a 10 to 30V dc signal. A dc device such as a photoelectric sensor or optical encoder

typically supplies the Gate input. Gate input signals must be greater than 100

microseconds in duration; the time between successive Gate inputs must be greater

than the minimum scan time for the light screen array

(see section 4.5 for scan time

information).

Advertising